Skip to main content
Phytion EcoTracer MONITOR. MEASURE. MONETIZE.
WORKSPACE Facilities Change workspace
FACILITYGreen Plains OrganicsFARM-IL-01
CURRENT CONTEXTGreen Plains Organics
SECTIONEquipment
PAGEValves
FACILITY EQUIPMENT

Valves Overview

Green Plains Organics · FARM-IL-01

Routing configuration, tank connections and maintenance records.

Valves Overview summary

Registered valves
4valves
Current facility
Active register group
4valves
ACTIVE, OPEN or CLOSED
Register status OPEN
3valves
Registered configuration
Maintenance review
0valves
Missing date or at least one year old

Green Plains Organics · FARM-IL-01

Valve inventory

Routing & configuration 4 valves

Each card opens the valve's equipment record, normal position and tank connection.

Operations overview
MV-008-INGreen Plains Feed INLET ValveBALL Registered statusOPEN Inspect
MV-008-INRegister · OPEN

Green Plains Feed INLET Valve

BALL · Valve equipment

Configured normal position
OPENNormally Open
Configured direction
INLET
Connected tankGreen Plains Feed TankMT-008
Manufacturer
Bray
Model
Series-740
Last maintenance
Sep 2, 2026Recorded within the past year
MV-008-OUTGreen Plains Feed OUTLET ValveBALL Registered statusOPEN Inspect
MV-008-OUTRegister · OPEN

Green Plains Feed OUTLET Valve

BALL · Valve equipment

Configured normal position
CLOSEDNormally Closed
Configured direction
OUTLET
Connected tankGreen Plains Feed TankMT-008
Manufacturer
Bray
Model
Series-740
Last maintenance
Sep 2, 2026Recorded within the past year
MV-007-INGreen Plains Receiving INLET ValveKNIFE_GATE Registered statusOPEN Inspect
MV-007-INRegister · OPEN

Green Plains Receiving INLET Valve

KNIFE_GATE · Valve equipment

Configured normal position
OPENNormally Open
Configured direction
INLET
Connected tankGreen Plains Receiving TankMT-007
Manufacturer
DeZURIK
Model
KGC-MD
Last maintenance
Sep 3, 2026Recorded within the past year
MV-007-OUTGreen Plains Receiving OUTLET ValveKNIFE_GATE Registered statusCLOSED Inspect
MV-007-OUTRegister · CLOSED

Green Plains Receiving OUTLET Valve

KNIFE_GATE · Valve equipment

Configured normal position
CLOSEDNormally Closed
Configured direction
OUTLET
Connected tankGreen Plains Receiving TankMT-007
Manufacturer
DeZURIK
Model
KGC-MD
Last maintenance
Sep 3, 2026Recorded within the past year

Configuration record. Normal position, direction and register status describe the saved equipment configuration. A timestamped position reading is not available here. The blueprint and its arrows are illustrative.

Maintenance review. The review count includes missing dates and dates on or before Oct 17, 2025. This is a date-age check; the equipment's required service interval may differ.